- The picture above shows the maximum power one building distributor can cover.
This supports for stable power distribution to run.
it is highly recommended to install the power supply to the 3rd floor distributor to
provide ample power between the floor 1 through floor 8 distributors.
Power source: (DC28V/5A)
The following wiring is recommended for stable power supply and to prevent
possible interference.
- Disconnect from the 8th floor distributor OUT-terminal to 7th wire (+28V VCC)
in the 9th floor distributor IN-terminal, because the 3rd floor distributor power
supply (28V/5A) will be transmitted to each floor distributors from floors 9 through 16.
- Disconnect from the 16th floor distributor OUT-terminal to 7th wire(+28V VCC)
in the 17th floor distributor IN-terminal, because the 12rd floor distributor power
supply (28V/5A) will be transmitted to each floor distributors from floors 17 through 23.
- Disconnect from the 24th floor distributor OUT-terminal to 7th wire(+28V VCC)
in the 25th floor distributor IN-terminal, because the 20rd floor distributor power
supply (28V/5A) will be transmitted to each floor